Test Required for ASTM A53 steel pipe
Test Required for ASTM A53 steel pipe
ASTM A53 standard have some basic requirements for seamless and welded steel pipes.
1. Hydrostatic Testing: test pressures for plain and threaded and coupled pipe are specified. Hydrostatic pressure shall be maintained for more than 5 seconds for all sizes of seamless and welded steel pipe.
2. Mechanical Tests:
---Tensile Test: Two transverse tests required on the welded steel pipe for NPS 8 and larger, one across the weld and one opposite the weld.
---Flattening Test: On welded steel pipe for NPS 2 and larger, STD and XS wall (not required for XXS pipe)
---Bending Test (cold): For NPS 2 and under, XS wall and under; for NPS 1-1/4 and under, XXS wall
---Number of Tests: Seamless and welded steel pipe – bending, flattening, tensile on one length of pipe from each lot of 500 lengths, or less, of each pipe size.
There are also more test needed, check standard download for more info.